tailieunhanh - Fundamentals of Mechanical Ventilation

A gate valve is a linear motion valve used to start or stop fluid flow; however, it does not regulate or throttle flow. The name gate is derived from the appearance of the disk in the flow stream. Figure 4 illustrates a gate valve. The disk of a gate valve is completely removed from the flow stream when the valve is fully open. This characteristic offers virtually no resistance to flow when the valve is open. Hence, there is little pressure drop across an open gate valve. When the valve is fully closed, a disk-to-seal ring contact surface exists for 360°, and good sealing is. | Fundamentals of Mechanical Ventilation A short course on the theory and application of mechanical ventilators Robert L. Chatburn BS RRT-NPS FAARC Director Respiratory Care Department University Hospitals of Cleveland Associate Professor Department of Pediatrics Case Western Reserve University Cleveland Ohio Mandu Press Ltd. Cleveland Heights Ohio roanclu pr Esjsj Published by Mandu Press Ltd. PO Box 18284 Cleveland Heights OH 44118-0284 All rights reserved. This book or any parts thereof may not be used or reproduced by any means electronic or mechanical including photocopying recording or by any information storage and retrieval system without written permission from the publisher except for the inclusion of brief quotations in a review. First Edition Copyright 2003 by Robert L. Chatburn Library of Congress Control Number 2003103281 ISBN printed edition 0-9729438-2-X ISBN PDF edition 0-9729438-3-8 First printing 2003 Care has been taken to confirm the accuracy of the information presented and to describe generally accepted practices. However the author and publisher are not responsible for errors or omissions or for any consequences from application of the information in this book and make no warranty express or implied with respect to the contents of the publication. Table of Contents 1. INTRODUCTION TO Self Assessment True or Multiple Key 2. INTRODUCTION TO Types of Conventional High Frequency Patient-Ventilator Positive Pressure Negative Pressure Power Positive Pressure Negative Pressure Control Patient Monitoring Graphic Self Assessment True or Multiple Key 3. HOW VENTILATORS Input .

TỪ KHÓA LIÊN QUAN
crossorigin="anonymous">
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.