tailieunhanh - HOW TO USE AND CARE FOR YOUR DIRECTOR KEROSENE HEATER
• Where serious consequences might result from any proven charge (including for example the possibilities of dismissal, demotion, removal of rights as a researcher or public pronouncement on their professional failings) the individual should have the right to professional representation and/or assistance, including legal representation in appropriate cases: it should be for the employing organisation to decide what representational rights are appropriate. • Where a charge is brought against someone funded by RCUK (including acting as a supervisor for an RCUK postgraduate student or engaged with peer review activities), even if it is about work not connected with a grant from a UK Research Council, then this must be reported. | How to Use and Care For Your Director Kerosene Heater Owner s Guide KERO5UN QUICK REFERENCE Specifications 2 Special Features 2 Safety Features 2 Unpacking 3 Assembly 3 Serial Number 4 Ventilation. 6 Fueling 5 Safety Reminders 6 Lighting 7 Automatic Lighting Lighting with a Match Adjusting the Flame To Extinguish the Flame 9 Troubleshooting 10 Cleaning the Wick 11 Replacing Igniter 14 Replacing Wick 11 Parts and Service 14 Limited Warranty 16 Specifications Model Director Heater Rating 11 700 BTU hr. This includes heat produced by the Director plus heat that would be generated if water of combustion were condensed. This rating and Heater Output below should be used when making comparisons between heaters of different manufacture. Heater Output 11 000 BTU hr. This rating is heat produced by the Director or the amount of heat delivered to the room. The wick-fed Kero-Sun Director is more than o efficient. Burning Time 23-32 hours. Burning time is a function of the condition of the wick the setting of the flame regulator knob fuel quality and atmospheric conditions Typical Room Sizes or approx. 400 . 2 0 28 14 2 0 The area to be heated varies with outside air temperature insulation R factors and square footage of the windows The room sizes given above assume the Kero-Sun is the only heat source for the room. Fuel Type Kerosene Fuel Tank Capacity gallons Batteries 2 size D cells included Dimensions Height 19 in. width 21 in. depth 19 in. Weight lb. empty Safety Features UL Listed Shut-off Protection Automatic shut-off extinguishes the flame if heater is jarred. Wick-feed Fuel remains below burner and is unpressurized. If flame goes out fuel flow stops fuel cannot flood burner. Low Center of Gravity Weight concentrated in base reducing chance of tip-over. Rubber Seals Burner wick winder fuel cap and other joints sealed with oil-proof rubber to prevent leaks if tip-over occurs. Double-wall Construction Stainless steel heat shield keeps sides and back .
đang nạp các trang xem trước