tailieunhanh - Báo cáo khoa hoc:" Detection of anticipatory postural adjustments prior to gait initiation using inertial wearable sensors"

Tuyển tập báo cáo các nghiên cứu khoa học quốc tế ngành y học dành cho các bạn tham khảo đề tài: Detection of anticipatory postural adjustments prior to gait initiation using inertial wearable sensors | Martinez-Mendez et al. Journal of NeuroEngineering and Rehabilitation 2011 8 17 http content 8 1 17 Iril JOURNAL OF NEUROENGINEERING NCR AND REHABILITATION RESEARCH Open Access Detection of anticipatory postural adjustments prior to gait initiation using inertial wearable sensors Rigoberto Martinez-Mendez Masaki Sekinet and Toshiyo Tamura Abstract Background The present study was performed to evaluate and characterize the potential of accelerometers and angular velocity sensors to detect and assess anticipatory postural adjustments APAs generated by the first step at the beginning of the gait. This paper proposes an algorithm to automatically detect certain parameters of APAs using only inertial sensors. Methods Ten young healthy subjects participated in this study. The subjects wore an inertial unit containing a triaxial accelerometer and a triaxial angular velocity sensor attached to the lower back and one footswitch on the dominant leg to detect the beginning of the step. The subjects were standing upright on a stabilometer to detect the center of pressure displacement CoP generated by the anticipatory adjustments. The subjects were asked to take a step forward at their own speed and stride length. The duration and amplitude of the APAs detected by the accelerometer and angular velocity sensors were measured and compared with the results obtained from the stabilometer. The different phases of gait initiation were identified and compared using inertial sensors. Results The APAs were detected by all of the sensors. Angular velocity sensors proved to be adequate to detect the beginning of the step in a manner similar to the footswitch by using a simple algorithm which is easy to implement in low computational power devices. The amplitude and duration of APAs detected using only inertial sensors were similar to those detected by the stabilometer. An automatic algorithm to detect APA duration using triaxial inertial sensors was proposed. .

TÀI LIỆU LIÊN QUAN