tailieunhanh - Electrical Power Systems Quality, Second Edition phần 8

Mặc dù các DG không có nỗ lực để điều chỉnh điện áp, nó vẫn còn hữu ích cho các mục đích điều chỉnh điện áp trong điều kiện tải chế bằng cách thay một số điện hoạt động và phản ứng. Ngoài ra, khách hàng sở hữu DG có thể được khai thác đơn giản bằng cách điều hành lưới điện và hỗ trợ một phần hoặc tất cả các dòng off-tải của khách hàng. | Power Quality Benchmarking Power Quality Benchmarking 369 overtravel and sympathetic tripping since this can circumvent measures taken specifically to improve power quality. Circuit breaker with relay. A circuit breaker will schedule an opening event if its currents adjusted by the associated current transformer ratio exceed the associated relay pickup setting. If the relay has an instantaneous setting and the current exceeds that level the event time will be the relay instantaneous pickup time plus the breaker clearing time. Otherwise the event time will depend on the relay s time-current characteristic. If the relay is of the definite-time type this will be a constant relay setting plus breaker clearing time. If the relay is of the inverse type this will be a current-dependent time plus the breaker clearing time. We use approximate time-current curves for both relays and reclosers. If the fault current is removed before the breaker opens an internal relay travel state variable is updated. This may produce a sympathetic trip due to relay inertia. If no sympathetic trip is predicted an event for full reset is then pushed onto the priority queue. The circuit breaker may have one or two reclosure settings. If the breaker has opened it will schedule a closing operation at the appropriate time. In case there are subsequent events from other devices the breaker model must manage an internal state variable of time accumulated toward the reclose operation. The time between opening and reclosing is a constant. Once the breaker recloses it follows the defined fault-clearing behavior. There may be two reclosings at different time settings before the breaker locks out and pushes no more events. Fault. A permanent fault will not schedule any events for the priority queue but will have an associated repair time. Any customers without power at the end of the fault simulation will experience a sustained interruption of duration equal to the repair time. A temporary fault will .

TỪ KHÓA LIÊN QUAN
crossorigin="anonymous">
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.