tailieunhanh - Báo cáo y học: " Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo®-derived cardiac output measurements: a prospective comparison study"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Critical Care giúp cho các bạn có thêm kiến thức về ngành y học đề tài: Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo®-derived cardiac output measurements: a prospective comparison study. | Available online http content 13 6 R179 Research Variations in arterial blood pressure are associated with parallel changes in FlowTrac Vigileo -derived cardiac output measurements a prospective comparison study Savvas Eleftheriadis1 Zisis Galatoudis1 Vasilios Didilis2 loannis Bougioukas2 Julika Schon1 Hermann Heinze1 Klaus-Ulrich Berger1 and Matthias Heringlake1 Department of Anesthesiology University General Hospital of Alexandropoulis Dragana Alexandropoulis PC 68100 Greece 2Department of Cardiothoracic Surgery University General Hospital of Alexandropoulis Dragana Alexandropoulis PC 68100 Greece Corresponding author Matthias Heringlake Heringlake@ Received 20 Jul 2009 Revisions requested 15 Sep 2009 Revisions received 21 Sep 2009 Accepted 9 Nov 2009 Published 9 Nov 2009 Critical Care 2009 13 R179 doi cc8161 This article is online at http content 13 6 R1 79 2009 Eleftheriadis et al. licensee BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License http licenses by which permits unrestricted use distribution and reproduction in any medium provided the original work is properly cited. Open Access Abstract Introduction The reliability of autocalibrated pressure waveform analysis by the FloTrac-Vigileo FTV system for the determination of cardiac output in comparison with intermittent pulmonary arterial thermodilution lPATD is controversial. The present prospective comparison study was designed to determine the effects of variations in arterial blood pressure on the reliability of the FTV system in patients undergoing coronary artery bypass grafting CABG . Methods Comparative measurements of cardiac output by FTV derived from a femoral arterial line software version and IPATD were performed in 16 patients undergoing elective CABG in the period before institution of cardiopulmonary bypass. Measurements were performed after induction

TÀI LIỆU LIÊN QUAN
TỪ KHÓA LIÊN QUAN
crossorigin="anonymous">
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.