tailieunhanh - Disposable carbon electrodes as an alternative for the direct voltammetric determination of alkyl phenols from water samples

Disposable sensors based on a pencil graphite electrode were described for detection of alkyl phenols. The performances of the disposable bare pencil graphite electrode (PGE) and PGE modified with carbon nanotubes, regarding the cyclic and differential pulse voltammetric determination of 4-nonylphenol, 4-octylphenol, and 4-tert-octylphenol, were compared. Some experimental variables of the electrode surface pretreatment and measurement parameters were optimized. Using a phosphate buffer solution (pH ) as the supporting electrolyte, alkyl phenols gave a well-defined oxidation peak at about 700 mV vs. Ag/AgCl. |