tailieunhanh - Experimental study of bubble behaviors and CHF on printed circuit board (PCB) in saturated pool water at various inclination angles

The surface inclination angles were 0 , 45 , 90 , 135 , and 180 . Results showed the Onset of Nucleate Boiling (ONB) heat flux increased with increasing heater orientation from 0 to 90 , while early ONB occurred when the heater faced downwards (135 and 180 ). The nucleate boiling was observed to be unstable at low heat flux (1e21% of CHF) and changed into typical boiling when the heat flux was above 21% of CHF. | Experimental study of bubble behaviors and CHF on printed circuit board (PCB) in saturated pool water at various inclination angles

TỪ KHÓA LIÊN QUAN
crossorigin="anonymous">
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.